Conventional Fire Detection and Alarm Systems – MM.BRS.YD.058

ANC’s Conventional Fire Alarm System is a reliable solution for small to mid-size buildings, using zone-based (Zones) segmentation to quickly identify alarm locations. It supports 2–16 zone panels with fully supervised circuits against open/short faults and complies with EN 54 requirements for stable, dependable operation. Contact ANC to select the right configuration for your project in Saudi Arabia.

Category:

ANC’s Conventional Fire Alarm System is a reliable solution for small to mid-size buildings, using zone-based (Zones) segmentation to quickly identify alarm locations. It supports 2–16 zone panels with fully supervised circuits against open/short faults and complies with EN 54 requirements for stable, dependable operation. Contact ANC to select the right configuration for your project in Saudi Arabia.


Arif Alnahdi ANC Conventional Fire Alarm System is a practical and reliable solution designed to protect small and medium-sized buildings. The system is based on dividing the facility into independent Zones, allowing quick fire location identification and faster emergency response.

It is characterized by stable performance, easy operation, and full compliance with European fire alarm standards.

Technical Specifications of the Conventional Fire Alarm System MM.BRS.YD.058

  • System Type: Conventional Fire Detection & Alarm System
  • Number of Zones: 2 / 4 / 8 / 16 Zones (depending on the control panel model)
  • Zone Capacity: Up to 32 detectors or manual call points per zone
  • Power Supply: 230V AC – 50Hz
  • Sounder Outputs: 1 or 2 Sounder Outputs (depending on the model)
  • Control: Microprocessor Controlled
  • Event Memory: Up to 1000 events
  • Circuit Monitoring: Full monitoring of zone circuits and sounder circuits against open circuit and short circuit faults
  • Standards Compliance:
    EN 54-2 / EN 54-4
    EN 54-5 / EN 54-7 (for detectors)
  • Operating Interface:
    LED indicators for Fire, Fault, Power Supply, and internal buzzer (Piezo Buzzer)
  • Installation: Surface Mount (Wall Mounted)
  • Protection: PCB protection against humidity and corrosion (PCB Protection)
  • Expandability: Supports connection of up to 32 Repeater Panels via RS-485

Main Components of the Fire Alarm System

  • Conventional Fire Alarm Control Panels (2–16 Zones)
  • Optical Smoke Detectors
  • Heat Detectors (Fixed Temperature / Rate-of-Rise)
  • Multi-Sensor Detectors (Smoke + Heat)
  • Manual Call Points (Indoor and Outdoor IP65)
  • Alarm Bells and Sounders with Strobe Light
  • Repeater Panels
  • Sounder and Power Expansion Modules

Key Features of the ANC Conventional Fire Alarm System

  • Stable and Reliable Operation: Provides consistent performance suitable for long-term daily operation
  • User-Friendly Interface: Simple interface with a limited number of control buttons
  • Quick Testing: One-button test for all LED indicators
  • Clear Zone Identification: Helps accurately locate the fire through the zone-based detection system
  • Flexible Control: Ability to disable zones or sounders when needed
  • Easy Maintenance: Clear design with readily available spare parts
  • Interference Resistance: High protection against electromagnetic interference (EMI)

Suitable Applications for Conventional Fire Alarm Systems

  • Office buildings and administrative facilities
  • Small schools and universities
  • Clinics and medical centers
  • Retail shops and commercial stores
  • Small to medium warehouses
  • Low-rise residential buildings

Contact Arif Alnahdi ANC now to get the certified Conventional Fire Alarm System, along with technical consultation to select the most suitable configuration for your project in Saudi Arabia!

Reviews

There are no reviews yet.

Be the first to review “Conventional Fire Detection and Alarm Systems – MM.BRS.YD.058”

Your email address will not be published. Required fields are marked *

Product Guides

لا توجد دلائل متوفرة لهذا المنتج حالياً.

Related Products

Placeholder

Commercial Kitchen Fire Suppression System – Mechanical Control System – BSI Approved

باب طوارئ فولاذ مقاوم للحريق

120-Minute Fire-Rated Steel Emergency Door – 1000 × 2100 mm – UL/SASO/FM/NFPA Certified

وحدة التحكم الذكية لمخمدات دخان الحريق - MM.KTL.YD.005

Intelligent Smoke Damper Control Modules - MM.KTL.YD.005

Scroll to Top